Sony PDW-F70 DVD Recorder User Manual


 
95
System Menu
Chapter 6 Menus
ESSENCE MARK [>
EssnceMk]
SDI OUT [>> SDI out]: Select
whether to output
essence marks in the
VANC of HD/SDSDI
output.
*ON [>>> ON]: Output.
OFF [>>> OFF]: Do not output.
SD VANC LINE [>> SDI
line]: When SDI OUT is
set to “ON”, select the
line of SDSDI output in
which to output essence
marks.
12LINE [>>> 12 line] to 19LINE [>>> 19 line]: Select in the
range line 12 to line 19.
Factory default setting: *17LINE (line 17)
HD VANC LINE [>> HD line]:
When SDI OUT is set to
“ON”, select the line of
HDSDI output in which to
output essence marks.
9LINE [>>> 9 line] to 20LINE [>>> 20 line]: Select in the
range line 9 to line 20.
Factory default setting:*17LINE (line 17)
HD VANC INPUT [> HD
VANC IN]: Make settings
related to recording of the
VANC data contained in
HDSDI input.
LINE [>> Line]: Select the
line whose VANC you
want to record.
*OFF [>>> OFF]: Do not record VANC from any line.
9LINE [>>> 9 LINE] to 20LINE [>>> 20 line]: Select from the
range line 1 to line 20.
Note
When this item is set to any setting other than OFF, VANC
packet information is saved in the DATA ITEM section of MXF
files.
DID [>> DID]: Select the DID
of the VANC you want to
record.
00 [>>> 00] to FF [>>> FF]
Factory default setting: *00 [>>> 00]
SDID [>> SDID]: Select the
SDID in the VANC you
want to record.
00 [>>> 00] to FF [>>> FF]
Factory default setting: *00 [>>> 00]
DATA ITEM OUT [> DATA ITEM]: Specify whether to include
the information from recorded VANC packets in data items
in the DATA ITEM section of MXF files.
OFF [>> OFF]: Do not include VANC packet information in
data items.
*ON [>> ON]: Include VANC packet information in data items.
Note
Set this menu item to OFF when you connect a nonlinear
editing system that does not support DATA ITEM.
SETUP BANK OPERATION [Setup Bank]: Settings related
to menu bank operations
Description
Menu bank: This unit allows three different complete sets of menu settings to be saved in what are termed “menu banks”
numbered 1 to 3.
RECALL BANK 1 [> Recall 1]: Recall menu settings from
menu bank 1.
Operate with the following procedure.
(1) Select the bank you want to recall, then press the ,/OUT
button.
Message “RECALL OK?” appears.
(2) To recall, press the SET button.
To quit recalling, press the RESET button
RECALL BANK 2 [> Recall 2] :Recall menu settings from
menu bank 2
RECALL BANK 3 [> Recall 3]: Recall menu settings from
menu bank 3.
SAVE BANK 1 [> Save 1]: Save current menu settings to
menu bank 1.
Operate with the following procedure.
(1) Select the bank you want to save, then press the ,/OUT
button.
Message “SAVE OK?” appears.
(2) To save, press the SET button.
To quit saving, press the RESET button.
SAVE BANK 2 [> Save 2]: Save current menu settings to
menu bank 2.
SAVE BANK 3 [> Save 3]: Save current menu settings to
menu bank 3.
METADATA [Metadata]: Metadata settings Description