Avaya S8400 Home Theater Server User Manual


 
Enabling SIPI
Installing and Configuring the Avaya S8400 Media Server February 2006
45
1. Type add cabinet n (where n is the cabinet number) and press Enter for each stack of
Media Gateways controlled by one TN8412AP SIPI circuit pack.
A cabinet is defined as up to five G650 Media Gateways mounted in a rack and
TDM-connected.
2. Fill in the location and carrier type for media gateways 2(B), 3(C), 4(D), and 5(E).
Enabling SIPI
These steps enable the SIPI circuit pack and allow the SIPI to control the port network.
1. Type change system-parameters ipserver-interface and press Enter.
2. On the IP Server Interface System Parameters screen, verify that the Primary Control
Subnet Address is correct.
The subnet address must match the most significant 3 octets (the first 3 groups of digits in
the subnet address) of the Media Gateway’s Server IP address (the server that controls
the port network). Use configure server on the Maintenance Web Interface to see the
IP address to match.
An asterisk (*) to the right of the Subnet Address field means that the subnet address
displayed is not the correct one. Avaya Communication Manager does not have the subnet
information.
add cabinet 1 Page 1 of 1
CABINET
CABINET DESCRIPTION
Cabinet: 1
Cabinet Layout: G650-rack-mount-stack
Cabinet Type: expansion-portnetwork
Number of Portnetworks: 1
Survivable Remote EPN? n
Location: 1 IP Network Region:1
Cabinet Holdover: A-carrier-only
Room: Floor: Building:
CARRIER DESCRIPTION
Carrier Carrier Type Number
E not-used PN 09
D not-used PN 09
C not-used PN 09
B G650-port PN 09
A G650-port PN 09