Q-See QC40198 Flat Panel Television User Manual


 
MAIN MENU QC40198 User Manual
59 | Page
5.3.8 Pan/Tilt/Zoom
The pan/tilt/zoom setup includes the following items. Please select channel first. See Figure 5-22.
Protocol: Select corresponding PTZ protocol such as PELCOD.
Address: input corresponding PTZ address.
Baud rate: Select baud rate.
Data bit: Select data bit.
Stop bit: Select stop bit.
Parity: There are three choices: none/odd/even.
After completing the setup click save button, system goes back to the previous menu.
For detailed setup, please refer to Chapter 4.9 preset/patrol/pattern/scan.
Figure 5-22
5.3.9 Display
Display setup interface is shown below. See Figure 5-23.
Transparency: Here you can adjust transparency. The value ranges from 128 to 255.
Channel name: Here you can modify channel name. System supports up to 25-digits. Please note all your
modifications here only apply to combo DVR local end. You need to open web or client end to refresh channel
name.
Time display: You can select to display time or not when system is playing back.
Channel display: You can select to display channel name or not when system is playing back.
Overlay information: System displays some information on the screen for your reference.
Resolution: There are five options: 1400×900(default), 1280×1024, 1280×720, 1024×768, 800×600. Please
note the device needs to reboot to activate setup changes.
Display mode: You can select from the dropdown list.
Enable tour: Activate tour function.
Interval: Input proper interval value here. The value ranges from 5-120 seconds. In tour process, you can use
mouse or click Shift to turn on window switch function.
Stands for opening switch function, stands for
closing switch function.
Motion tour type: System supports 1/8 window tour.
Alarm tour type: System supports 1/4/9/16 window tour.
Please highlight icon
to select the corresponding function.