Switch Setting of Link Unit
Baud rate: 19200bps
PLC System Memory Setting (in case of a communication port)
Baud rate: 19200bps
Available Memory
*
1To set up Fn (file register), input [File No.] + [: (colon)] + [address]
Set the memory to the extent of the memory range of each PLC model.
Use TYPE number to assign indirect memory for macro programs.
SW0
Swtich
SW1
SW2
SW3-1
SW3-2
SW3-3
SW3-4
SW4
SW7
4
1
0
OFF
ON
OFF
ON
0
ON
Setting Contents
Command mode
Station address (lower half)
Station address (upper half)
Not used
4-wire system
Not used
Even parity
Baud rate
0: 19200 1: 9600 2: 4800 3: 2400
4: 1200 5: 600
Teminating resistance provided
0#0236
#0237
0110000
10000000
D7 D6 D5 D4 D3 D2 D1 D0
System memory
15 Sharp PLC • 1
<E.g.> F1 : 00002
File No.
Address
Colon
Memory TYPE Remarks
X9XXX (register) 0
XXXXX (relay) 1 as word device
EXXXX (self-diagnosis) 2
bXXXX (timer counter) 3
Fn (file register) 7
*
1