2 - 136
Wiring Diagram 4
RS-422
Wiring Diagram 5
53 Automationdirect PLC
Wiring Diagram 3
Wiring Diagram 6
POD (CN1)
D-sub 25pin(Male: )
FG
SD
RD
RS
CS
1
2
3
4
5
TXD
RXD
PLC
D-sub 15pin(Male: )
RTS
CTS
0V
2
3
4
5
7
SG 7
* Use twist shielded cables.
*1 High density D-sub 15pin
POD (CN1)
D-sub 25pin(Male: )
FG
SD
RD
RS
CS
1
2
3
4
5
TXD
RXD
PLC
D-sub 15pin(Male: )
0V
2
3
13
SG 7
* Use twist shielded cables.
POD (CN1)
D-sub 25pin(Male: )
FG
+SD
-SD
+RD
-RD
1
12
13
24
25
RXD+
RXD-
PLC
D-sub 25pin(Male: )
CTS1+
TXD1+
TXD1-
RTS1+
RTS1-
CTS1+
9
10
11
14
16
18
19
23
SG 7
SG 7
* Use twist shielded cables.
POD (CN1)
D-sub 25pin(Male: )
FG
+SD
-SD
+RD
-RD
1
12
13
24
25
TXD3+
TXD3-
PLC
D-sub 25pin(Male: )
RXD3+
RXD3-
12
13
24
25
SG 7SG 7
In case SU-6M, it is possible
to use terminal blocks.
* Use twist shielded cables.