Graco TI12552a TV Cables User Manual


 
Color Change
312779E 109
F
IG
. 117: Color Change Chart 9
Valve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A A A
Catalyst Change B Air Chop Time B
Solvent Chop Time
First Purge (one of these) 3rd Flush Chop Time
Air Purge
Solvent Purge Final Purge (one of these)
3rd Flush Valve
Dispense A A AA
Dispense B BB
Gun Flush Box Output #1
Gun Flush Box Output #2
012 3 4 5 6
Color Pur
g
e Time 0->1
Color Fill Time 1->2
First Pur
g
e Time 2->3
Chop Time (air/solvent or air/3rd flush) 3->4
Final Pur
g
e Time 4->5
Mixed Fill Time 5->6
Notes: Load tables from new recipe
Purge from old recipe
Fill from new recipe
Chart 9: A1-A2, same B without Dump Valves, 1 GFB
ProMix 2KS Recipe Change
F
IG
. 118: Color Change Chart 10
Valve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A
Catalyst Change B
P0 P1 P2
Color Pur
g
e Time P0->P1
Catalyst Pur
g
e Time P1->P2
Air Chop Time
Solvent Chop Time
First Purge (one of these) 3rd Flush Chop Time
Air Purge
Solvent Purge Final Purge (one of these)
3rd Flush Purge
Dispense A
Dispense B
Gun Trigger(s) by Operator
M0 M1 M2 M3
First Pur
g
e Time M0->M1
Chop Time (air/solvent or air/3rd flush) M1->M2
Final Pur
g
e Time M2->M3
Notes:
All timing from Recipe 0
ProMix 2KS Recipe Change
Chart 10: Recipe X, 0, OR 61 to Recipe 0 with Dump Valves
Color/Catalyst Purge Timers are
independent of Mixed Material Purge
Timers.
A
B