Graco TI12552a TV Cables User Manual


 
Alarms and Warnings
312779E 115
Alarms and Warnings
NOTE: Do not use the fluid in the line that was dis-
pensed off ratio as it may not cure properly.
System Alarms
System alarms alert you of a problem and help prevent
off-ratio spraying. If an alarm occurs, operation stops
and the following occurs:
Buzzer sounds (for E-2 only; see page 32 to set for
all alarms).
Status bar on the EasyKey shows the alarm E-Code
with a description (see Table 16).
System Warnings
Table 16 lists the System Warning Codes. Warnings do
not stop operation or sound an alarm. They are saved in
the date/time stamped log, which can be viewed on a
PC, using the ProMix 2KS Web Interface (see manual
313386).
To Reset Alarm and Restart
NOTE: When an alarm occurs be sure to determine the
E-Code before resetting it. See Table 16. If you forget
which E-Code occurred, use the Alarms Screen (page
27) to view the last 10 alarms, with date and time
stamps.
To reset alarms, see Table 17. Many alarms can be
cleared by simply pressing the Alarm Reset
key.
Table 16: System Alarm/Warning Codes
Code Description Details
E-1 Communication Error Alarm Page 116
E-2 Potlife Alarm Page 116
E-3 Ratio High Alarm Page 117
E-4 Ratio Low Alarm Page 118
E-5 Overdose A/B Dose Too Short
Alarm
Page 119
E-6 Overdose B/A Dose Too Short
Alarm
Page 119
E-7 Dose Time A Alarm Page 120
E-8 Dose Time B Alarm Page 120
E-9 Mix in Setup Alarm Page 121
E-10 Remote Stop Alarm Page 121
E-11 Purge Volume Alarm Page 121
E-12 CAN Network Communication Error
Alarm
Page 122
E-13 High Flow Alarm Page 122
E-14 Low Flow Alarm Page 122
E-15 System Idle Warning Page 123
E-16 Setup Change Warning Page 123
E-17 Power On Warning Page 123
E-18 Defaults Loaded Warning Page 123
E-19 I/O Alarm Page 124
E-20 Purge Initiate Alarm Page 125
E-21 Material Fill Alarm Page 125
E-22 Tank A Low Alarm Page 125
E-23 Tank B Low Alarm Page 125
E-24 Tank S Low Alarm Page 125
E-25 Auto Dump Complete Alarm Page 126
E-26 Color/Catalyst Purge Alarm Page 126
E-27 Color/Catalyst Fill Alarm Page 126