Run Mode Screens
312779E 27
Alarms Screen
Two screens show the last 10 alarms. Use the Up
or
Down
keys to scroll between the two screens.
See Table 16 on page 115 for a list of alarm codes.
Level Control Screen
This screen shows the current volume for each fluid.
Adjust the current volumes on this screen, or use the tab
to go to Usage (Totals Screen, page 26). The Alarm
Level values may be adjusted using the advanced web
interface.
See F
IG
. 22. If the tank volume reaches the low-level
threshold, the EasyKey screen will display the Tank
Level Low alarm and prompt the user to do one of the
following:
1. Refill tank volume to clear the alarm.
2. Resume mixing by selecting “Spray 25% of Remain-
der.” If this selection is chosen, a second alarm will
occur after 25% of the remaining volume is mixed.
Refill tank volume to clear the alarm.