Setup Mode
34 312779E
DD Setup Mode
See F
IG
. 32 and F
IG
. 33. Selecting “DD” makes the
Dynamic Dosing Setup mode field appear. Select On to
enable DD setup mode, or Off to disable. See page 86
for further information.
Dose Time Alarm
Enter the dose time (1 to 99 seconds). This is the
amount of time allowed for a dose to occur before a
dose time alarm occurs.
Number of Guns
This field only appears if Run Mode is set to “Manual” or
Semi-Automatic” in Configure Screen 3, page 33.
Enter the number of spray guns (1 or 2).
NOTE: Only 1 gun is used in automatic mode.
Gun Flush Box (manual or semi-automatic mode)
This field only appears if Run Mode is set to “Manual” or
Semi-Automatic” in Configure Screen 3, page 33.
Enter the number of gun flush boxes (Off, 1, or 2).
Configure Screen 5
Flow Control
This field only appears if Run Mode is set to “Automatic”
in Configure Screen 3, page 33. Select On or Off.
If set to “On,” Advanced Setup Screen 5, page 41 is
added.
Special Outputs
Select special outputs (0-4). Each output has two differ-
ent start times and durations.
Solvent Monitor
Select solvent monitor (Off, Flow Switch, or Meter).
Web Browser IP
The default web browser IP address prefix is
192.168.178.__ Assign a unique number for each
EasyKey in your system (1-99) and enter it here.
F
IG
. 32. Configure Screen 4, dynamic dosing
selected
F
IG
. 33. Configure Screen 4, dynamic dosing setup
mode enabled
F
IG
. 34. Configure Screen 5