Alarm Troubleshooting
312779E 121
E-9: MIX IN SETUP ALARM
Cause Solution
Attempt to operate system while in Setup mode. System must be in Standby to change current recipe,
and cannot be operated.
E-10: REMOTE STOP ALARM
Cause Solution
Automation has requested that the system abort all oper-
ations.
Abort operations. Troubleshoot automation system.
E-11: PURGE VOLUME ALARM
Cause Solution
ProMix 2KS solvent flow switch is not activated while
purging.
Verify that the gun is not shut off and that the solvent flow
switch is activated while purge is taking place.
Minimum flush volume is not achieved. Increase solvent supply or decrease minimum volume
setting.
No meter pulses during Color/Catalyst Dump. Color change solvent supply not set up or functional.
Check Color Change setup.
Table 17. Alarm Troubleshooting