Graco TI12552a TV Cables User Manual


 
Color Change
312779E 111
F
IG
. 121: Color Change Chart 13
Valve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A A A
Catalyst Change B
Air Purge
Solvent Purge
3rd Flush Purge
Dispense A A A A
Dispense B B B
Gun Trigger(s) by Operator
01 2
Color Fill Time 0->1
Mixed Fill Time 1->2
Notes: Load tables from new recipe
Purge from old recipe
Fill from new recipe
ProMix 2KS Recipe Change
Chart 13: Recipe 0 OR 61 to Recipe X without Dump Valves
F
IG
. 122: Color Change Chart 14
Valve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A A
Catalyst Change B B
P0 P1 P2 P3 P4
Color Pur
g
e Time P0->P1
Color Fill Time P1->P2
Catalyst Pur
g
e Time P2->P3
Catalyst Fill Time P3->P4
Air Chop Time
Solvent Chop Time
First Purge (one of these) 3rd Flush Chop Time
Air Purge
Solvent Purge Final Purge (one of these)
3rd Flush Valve
Dispense A AA
Dispense B BB
Gun Trigger(s) by Operator
M0 M1 M2 M3 M4
First Pur
g
e Time M0->M1
Chop Time (air/solvent or air/3rd flush) M1->M2
Final Pur
g
e Time M2->M3
Mixed Fill Time M3->M4
Notes: Load tables from new recipe
Purge from old recipe
Fill from new recipe
1st On/Start 1st On Length/Duration 2nd On/Start 2nd On Length
Special Output #1
Special Output #2
Special Output #3
Special Output #4
Recipe Change Purge Active Output
Recipe Change Fill Active Output
B
A
CC Pur
g
e/Fill Timers are independent
of Mixed Material Pur
g
e Timers. This
line defines when the Mixed Fill Time
begins. The longer of the two timers
defines when the Mixed Fill Time
begins.
ProMix 2KS Recipe Change
Chart 14: A1 to A2, B1 to B2 with All
A
B