15
4. Connection with external equipment (Monitor)
Setting the sync. polarity and output sync. signal
When the sync. polarity or sync. signal of a monitor to be connected is not adjusted to the initial setting of this unit, the image
may not be displayed correctly. In this case, adjust the sync. polarity and sync. signal output to the monitor.
When the image is displayed correctly, the setting is not required. (Refer to the operation manual of the monitor as for the sync.
polarity and sync. signal of the monitor.)
Displaying the menu
, The sync. polarity and sync. signal is set by the menu displayed on LCD.
, Make sure to turn off the power before setting.
Displaying “Memory SW Main Menu”
1 Press the POWER button while pressing the MEMORY button on the front
panel.
The menu for memory switch “Memory SW Main Menu” is displayed.
Displaying “Signal Adj Menu”
} Use the buttons on the remote control to display and set the items in this
menu.
2 Press the DOWN button to select “3. SIGNAL ADJUST : PUSH
[ ] ]” menu.
3 Press the RIGHT
button.
, The menu for signal setting, “Signal Adj Menu” is displayed.
, The sync. polarity, “SYNC” and output sync signals, “OUTPUT SYNC”
and “RGB SOG OUT” can be set in this menu.
Setting the sync. polarity “SYNC : NEGA POSI”
4 Press the UP or DOWN button to select “SYNC” .
, In the initial setting, “IN SYNC” is selected in “3.SIGNAL ADJ : PUSH
[ ] ]” . When other menu is selected, press the UP or DOWN
button to select “SYNC” .
The sync. polarity being selected, for example, “NEGA” is displayed.
Press the RIGHT or LEFT button to select “NEGA” or
“POSI” according to the polarity of the equipment to be connected.
Memory SW Main Menu
1.TIME ADJ :PUSH[>]
LCD
Memory SW Main Menu
3.SIGNAL ADJ:PUSH[>]
Signal Adj Menu
IN SYNC : TTL,SOG
Signal Adj Menu
SYNC : NEGA