Mitsubishi Electronics CP700E VCR User Manual


 
21
4. Connection with external equipment (RS-232C Interface)
4 Press the SET
SET
button.
, CHANGE : OK” is selected.
5 Select “OK”, then, press the SET
SET
button.
, The source image (input signal from the equipment connected) is displayed.
0 The setting of COMMAND TYPE is completed.
RS-232C DATA SIGNAL
RS-232C input connector port signal allocation
Pin No. Signal line name Description Directions (From VCP side)
1 F G Protective ---
2 T X D Transmitted data Output
3 R X D Received data Input
4 R TS Request to send Output
5 C T S Clear to send Input
6 D S R Data set ready Input
7 G N D Signal ground ---
20 D T R Data terminal ready Output
Setting the communication format of the computer
, Set the communication format as follows:
(1) Synchronizing system Asynchronous communication
(2) Data bit length 8 bits
(3) Parity bit Nothing
(4) STOP bit length 1
(5) Transmission order Sent from LSB
(6) Baud rate (Bit / Sec) 1200, 2400, 4800, 9600
RS-232C function
, This unit can be controlled through RS-232C terminal.
( The input of image data is not possible.)
Consult with the sales dealer for the details of controlling
method (protocol).
Pin connection
, Connect the unit with the host computer
through cross-over cable.
Cross-over cable