Operation and Maintenance
5-4
9123-A2-GB20-10
July 2000
LED Descriptions
The following table identifies the alarms that cause the Alarm LED to light. See
Table 5-2 and Table 5-3 for network and user data port interface LED information.
Table 5-1. General Status LEDs (1 of 2)
Label
Indication Color What It Means
OK Power and
Operational
Status
Green ON FrameSaver unit has power and it is
operational.
OFF – FrameSaver unit is in a power-on
self-test, or there is a failure.
ALM Operational
Alarm (Fail)
Red ON FrameSaver unit has just been reset,
or an error or fault has been detected.
Error/fault/alarm conditions:
H Alarm Indication Signal (AIS)
H CTS Down
H DLCI Down
H DTR Down
H Exceeded Error Rate (EER)
H LMI Down
H Loss of Signal (LOS)
H Out of Frame (OOF)
H Primary Clock Failed
H Self-Test Failed
H SLV Timeout
H Two Level-1 Users Accessing
Device
H Yellow Alarm Signal
OFF – No failures have been detected.
These alarms appear on the System and
Test Status screen. See
Health and Status
Messages
for additional information.
TST Test Mode Yellow ON Loopback or test pattern is in progress,
initiated locally, remotely, or from the
network.
OFF – No tests are active.