Paradyne 9123 Flat Panel Television User Manual


 
Setting Up NetScout Manager Plus for FrameSaver Devices
8-11
9123-A2-GB20-10
July 2000
" Procedure
1. Open a terminal window and go to $NSHOME/usr.
2. Copy an example or interface-specific file to a new file that contains the user
history table number.
3. Open the new file using a text editor.
The variables in the file are listed with their OIDs (Object IDs). The frame
relay interface number 101015001 must replace @IFN, and the DLCI number
to be monitored must replace @DLCI.
Example:
frCircuitSentFrames
Change “1.3.6.1.2.1.10.32.2.1.6.@IFN.@DLCI
to “1.3.6.1.2.1.10.32.2.1.6.101015001.301
The only valid interface number for a FrameSaver 9123 model is 101015001.
4. Edit the new file, as needed.
Refer to
Creating .UDH Files
and
Using Custom History
in the
NetScout Manager
Plus User Guide
for additional information.
See Appendix B,
SNMP MIBs and Traps, and RMON Alarm Default
, for OID
information for an interface.