Table 5-7. Health and Status Messages (2 of 3)
Message What It Indicates
Ethernet Link Down The Ethernet port is enabled, but communication
between the management system and the unit is
not currently possible on the port.
Lease Line Mode Active The FrameSaver unit is configured for leased line
operation (see Service Type on the Easy Install
screen).
Link
Down Administratively,
frame relay link
2
The specified frame relay link has been disabled
by the unit due to LMI Behavior conditions or LMI
Protocol on another link is in a failed state.
This is not an alarm condition so System
Operational appears, as well.
LMI Discovery in Progress,
frame relay link
2
Local Management Interface protocol discovery is
in progress to determine which protocol will be
used on the specified frame relay link.
LMI Down,
frame relay link
2
The Local Management Interface(s) has been
declared down for the specified frame relay link.
LOS at Network
1 A Loss of Signal (LOS) condition is detected on the
network interface. Clears when the ratio of ones to
zeros received is greater than or equal to 12.5%.
Possible reasons include:
H Network cable problem.
H No signal is being transmitted at the far-end
FrameSaver unit.
H T1 facility problem.
Network Com Link Down The communication link for the COM port is down,
and the COM port is configured for Net Link.
OOF at Network 1 An Out of Frame (OOF) condition is detected on
the network interface. Possible reasons include:
H Incompatible framing format between the
network and the FrameSaver unit.
H Network cabling problem.
H T1 facility problem.
2
frame relay link
is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.