Paradyne 9123 Flat Panel Television User Manual


 
Troubleshooting
6-10
9123-A2-GB20-10
July 2000
Table 6-1. Alarm Conditions (4 of 4)
Alarm Condition What To DoWhat It Indicates
Primary Clock Failed A failure of the configured
primary clock source for the
unit was detected and the
secondary clock is
providing the timing for the
unit.
This condition clears when
the configured primary
clock is restored.
H Check that the network cable
is securely attached at both
ends.
H Contact your network provider.
Self-Test Failure The unit did not pass its
basic verification tests
when it was powered on or
reset.
H Reset the unit.
H Contact your service
representative.
SLV Timeout,
DLCI
nnnn
,
frame relay link
1,2
An excessive number of
SLV communication
responses from the remote
system have been missed
on the specified multiplexed
DLCI and link.
If the frame relay link is
Net1-FR1, the timeout is on
the network FrameRly1
timeslot assignment.
When a hardware bypass-
capable device has been
detected at the other end of
the PVC and this condition
occurs, only user data for
EDLCI 0 will be transmitted
as long as the condition
exists.
Verify that the network LMI is up.
If it is, contact your network
service provider.
Two Level-1 Users
Accessing Device
Another user with Level-1
security access is currently
accessing the unit.
Be aware that actions of
the other user may override
your test commands and
configuration changes.
Wait until no other Level-1
users are accessing the unit if
testing or configuration will be
performed..
Yellow at Network 1 A yellow alarm signal is
received on the network
interface.
H Network cable problem.
H T1 facility problem.
H Check that your network cable
is securely attached at both
ends.
H Contact your network provider.
1
nnnn
indicates a DLCI number of 16 through 1007.
2
frame relay link
is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.