Paradyne 9123 Flat Panel Television User Manual


 
Configuration
3-31
9123-A2-GB20-10
July 2000
" Procedure
1. Select Frame Relay Network Assignments.
Main Menu
Configuration
Time Slot Assignment
Frame Relay Network Assignments
or
Main Menu
Easy Install
Time Slot Assignment Screen
(When Service Type is set to Frame Relay, the default.)
The Frame Relay Network Assignments screen appears. This screen
contains a matrix of the current assignment status of all time slots on
the network interface.
2. Enable or disable Time Slot Discovery.
When enabled, the unit examines all time slots not cross-connected to
other ports to determine which time slots are being used by the network
for frame relay traffic. These time slots are set to FrameRly1. This is
the factory default.
When disabled, time slot assignments must be manually configured.
3. If Time Slot Discovery is disabled, assign network time slots for use by frame
relay service, link 1, by typing FrameRly1 in the selected Network field.
4. Repeat Step 3 until all desired time slots are assigned.
5. S
ave the configuration.