Paradyne 9123 Flat Panel Television User Manual


 
Troubleshooting
6-18
9123-A2-GB20-10
July 2000
PVC Loopback
The PVC Loopback loops frames back to the selected interface on a per-PVC
basis. This test logically (not physically) loops back frames received from another
FrameSaver device through the selected frame relay PVC to the same
device.
Main Menu
Test
Network PVC Tests
98-16186
DTE
Network
PVC #
x
Network PVC Loopback
PVC #
x
Main Menu
Test
Data Port PVC Tests
PVC #
x
DTE
Network
98-16187
Port PVC Loopback
PVC #
x
Send Pattern
This test sends packets filled with a hexadecimal 55 test pattern and sequence
number over the selected interface and DLCI to another FrameSaver device.
To send a pattern test on a link:
Main Menu
Test
[Network PVC Tests/Data Port PVC Tests]
If the selected
DLCI is configured as . . .
Then . . .
And the default
Rate (kbps) setting is . . .
Standard (Disruptive) appears
after Test
100% of CIR
Multiplexed (Non-Disruptive)
appears after Test
10% of CIR
If the CIR is zero, the pattern will be sent at a rate of 1000 bps.