Paradyne 9123 Flat Panel Television User Manual


 
Operation and Maintenance
5-10
9123-A2-GB20-10
July 2000
Table 5-5. Device Messages (4 of 5)
Message What To DoWhat It Indicates
No Primary
Destination Link
DLCIs Available
New or Modify was
selected from the PVC
Connection Table, but even
though DLCIs are available
to form a connection, no
DLCIs are available on the
network link, which is a
suitable Primary PVC
Destination.
Configure additional DLCIs for
the network link and try again.
If a network DLCI has been
entered as a Source DLCI:
1. Change the Source DLCI to a
user data port DLCI.
2. Enter the network DLCI as the
PVC’s Primary Destination.
No Security Records
to Delete
Delete was selected from
the Administer Login
screen, and no security
records had been defined.
H No action is needed.
H Enter a security record.
Password Matching
Error – Re-enter
Password
Password entered in the
Re-enter Password field of
the Administer Logins
screen does not match
what was entered in the
Password field.
H Try again.
H Contact your system
administrator to verify your
password.
Permission Denied
(Seen at an FTP
terminal.)
A file transfer was
attempted, but the:
H User did not have
Level 1 security.
H See your system administrator
to get your security level
changed.
H Wrong file was specified
when the put command
was entered.
H Try again, entering the correct
file with the put command.
H User attempted to
upload a program file
from the unit.
H Enter the put command
instead of a get command;
you can only transfer files to
the unit, not from it.
See
Upgrading System
Software
.
Please Wait Command takes longer
than 5 seconds.
Wait until message clears.
Port Inactive The port is disabled, or it
supports synchronous data
and is configured for leased
line mode when a DTE
Loopback was started.
No action is needed.
Resetting Device,
Please Wait ...
Yes (or y) was entered in
the
Reset COM Port usage
field of the System Paused
menu.
No action is needed.