RS-485/NETWORK SET7
46 English
SETTINGS
4 Press the [ ] and [ ] buttons to select
“MANUAL,” then press the [ ] button
twice.
The last 3 digits of the address flash.
5 Press the [ ] and [ ] buttons to
change the setting, then press the [ ]
button.
The cursor moves to “DATA SPEED”.
6 When you have finished making the
settings, press the [EXIT/OSD] button.
Connect the digital video recorder’s RS-485 (A, B) control
terminals to the system controller, hard disk digital
recorder or similar device.
1 Press the [MENU] button.
The [MENU] button lights, and the <MAIN MENU> screen
is displayed.
2 Select “7. RS-485/NETWORK SET”, and
press the [ ] button.
The <RS-485 SET> screen is displayed.
[Settings] ( indicates default setting.)
3 Press the [ ] and [ ] buttons to select
the desired item, then press the [ ]
button.
4 Press the [ ] and [ ] buttons to
change the setting, then press the [ ]
button.
5 Repeat procedures 3 to 4 to set the
other items as needed.
6 When you have finished making the
settings, press the [EXIT/OSD] button.
The display returns to the normal screen.
RS-485 connections and settings
123456789
10 11 12 13 14 15 16 17 18 19
RS-485A
RS-485B
C
[ ] button[MENU] button [ ] button
[] button[EXIT/OSD] button
Item Setting Description
(1)
DATA
SPEED
2400
4800
9600
19200
Used to select the
communication speed.
(Unit: bps)
(2)
STATUS
INFO
ON
Enables status information to be
sent on the RS-485 line.
OFF Not set
(3)
ALARM
INFO
ON
Enables alarm information to be
sent on the RS-485 line.
OFF Not set
(4) ADDRESS
000 to 127
(001)
When connecting multiple
recorders, different address
numbers are set for each.
(1)
(2)
(3)
(4)
e07_l8hbc_hd_6.fm Page 46 Wednesday, July 30, 2003 3:13 PM