Sharp PG-M25X Projection Television User Manual


 
POWER button
Regarding the Lamp (cont.)
Removing and Install-
ing the Lamp Unit
Info
Be sure to remove the lamp unit by the
handle. Be sure not to touch the glass
surface of the lamp unit or the inside of
the projector.
To avoid injury to yourself and damage
to the lamp, be sure to carefully follow
the steps below.
Do not loosen other screws except for the
lamp cover and lamp unit.
Please refer to the installation manual
included with the lamp unit.
Make sure to read the manual that came
included with the lamp until.
1 Press on the projector to
turn off the power.
Wait until the cooling fan stops.
Warning!
Do not remove the lamp unit from the
projector right after use. The lamp will
be very hot and may cause burn or
injury.
2 Disconnect the power cord.
Unplug the power cord from the AC
socket.
Retract the antenna.
Leave the lamp until it has fully cooled
down (about 1 hour).
3 Remove the lamp unit cover.
Insert the antenna and turn over the
projector, and loosen the user service
screw that secures the lamp unit cover.
Then slide the cover in the direction of
the arrow.
Lamp
unit
BQC-PGM20X//1
AC socket
User service screw
-112
PG-M25X#E#p107_115.p65 02.4.29, 3:26 PM112