Sony HDW-S280 DVD VCR Combo User Manual


 
57
Recording UMIDs
Chapter 8 UMID Functions
from global UTC standard time allows correct UMIDs to
be generated.
To set the time zone, display the HOME page of the
function menu and proceed as follows:
1
Press the MENU button together with the SHIFT
button.
The error logger display appears.
For details on the error logger, refer to the
Maintenance Manual Volume 1.
2
Press the SETTING function button
3
Press the PREVIOUS or NEXT function button to
display OFFSET TO UTC in the time data display
area.
On the monitor screen, the ERROR LOGGER display
appears, and * mark appears before OFFSET TO UTC.
4
Turn the MULTI CONTROL knob or press the or +
function button to set the offset from UTC time.
For example, if the local time is 9 hours in advance of
UTC, set +09:00.
5
Press the SET function button.
The setting is registered.
00:26:23:09
ERROR
DATE
TC
DETAIL
SETTING
EXIT
ERR LOG
00:26:23:09
TAPE ERROR
PREVIOUS
NEXT
OFF
ON
EXIT
ERR LOG
00:26:23:09
OFFSET TO UTC 00:00
PREVIOUS
NEXT
EXIT
SET
ERR LOG
(014/023)
015 A PB DATA ERROR
ERROR LOGGER
016 V PB DATA ERROR
TAPE ERROR ON
WARNING ON
CONDITION ON
*OFFSET TO UTC +09:00
Push SET button
2001 12 24 23:59:59
014 REFERENCE MISSING