7-3 Extended Menu
Menu items in the 500s, relating to disc protection
Item number Item name Settings
501 STILL TIMER To protect the disc against shock and vibrations, and to lengthen the life
of the laser diodes, the unit automatically enters standby off mode
whenever a specified time elapses in a disc stop mode (stop mode or the
still picture mode of search mode). This allows you to set the time after
which the unit exits a disc stop mode and enters standby off mode.
0.5 s (0.5 sec)... 8 m (8 min)
... 30 m (30 min): Can be set in the range
from 0.5 seconds to 30 minutes.
off: Do not put into standby off mode.
Menu items in the 600s, relating to the time code reader, metadata, and UMID
Item number Item name Settings
601 VITC POSITION SEL-1 Select a line into which to insert VITC signals for DVCAM playback
signals.
a)
12 H (12 line)... 16 H (16 line)... 20 H (20 line) (in 525(U)/525(J) line
modes)
9 H (9 line)... 19 H (19 line)
... 22 H (22 line) (in 625 line mode)
Note
You can insert the VITC signal in two places. To insert it in two places, set
both items 601 and 602.
a)In the DVCAM format, VITC is recorded as VAUX (Video Auxiliary) data.
Because VITC is inserted into video signals by the VITC generator only during
playback, the insertion line can be specified only for playback.
602 VITC POSITION SEL-2 Select a line into which to insert VITC signals for DVCAM playback
signals.
a)
12 H (12 line)... 18 H (18 line)... 20 H (20 line) (in 525(U)/525(J) line
modes)
9 H (9 line)... 21 H (21 line)
... 22 H (22 line) (in 625 line mode)
Note
You can insert the VITC signal in two places. To insert it in two places, set
both items 601 and 602.
a)In the DVCAM format, VITC is recorded as VAUX (Video Auxiliary) data.
Because VITC is inserted into video signals by the VITC generator only during
playback, the insertion line can be specified only for playback.
626 TC MODE
b)
Select the time code recording method for files written or transferred by a
FAM or FTP connection.
e-prs (ext preset)
: Record the original time code of the clip file.
i-reg (int regen): Record clip file time code that is continuous with the
time code of the last frame of the last clip on the disc.
628 DF MODE Select either drop-frame mode or non-drop frame mode for the counter
(when 525(U) or 525(J) line mode is selected).
df (on (df))
: Drop-frame mode
ndf (off (ndf)): Non-drop frame mode
651 UMID SDI OUTPUT Select whether to output UMID in the VANC of the SDI output.
off: Do not output.
on
: Output.
See 7-3-3 “Using UMID Data” (page 84) for more information about