Tektronix 2200 TV Video Accessories User Manual


 
3-9
Switcher Module Description
Serial Reentry Module (064822)
There are two Serial Reentry Modules (SRE). The SRE Modules are used to
reenter some switcher outputs back into the switcher and enter some of the
internally generated signals into the switcher. Reentered signals are then
sent to the crosspoint module where they are treated the same as any other
video or key. Table 3-1 summarizes the uses of both the Reentry Modules.
SRE Module 1 is in input slot C6 and SRE 2 is in input slot C5.
Table 3-1. Reentry Module Signals
CROSSPOINT
INPUT
SIGNALS FOR SRE 1
CROSSPOINT
INPUT
SIGNALS FOR SRE 2
65 Reserved 73 Background 1
66 Reserved 74 Background 2
67 Reserved 75 Clipped Mask
68 Reserved 76 Reserved
69 Frame Store Video 77 M/E 2 Program Video
70 Frame Store Key 78 ME 2 Program Key
71 Black 79 M/E 1 Program Video
72 Test 80 M/E 1 Program Key