Toshiba L5232 TV Converter Box User Manual


 
6F8A0917
-
111
-
Changing the rate-of-change limit setting
The following is an example to change the limit value from 1.0% to 1.5%.
To change the control time, select the function “M2: LIMIT TIME.”
Switch operation Display example Description
M1: LIMIT RATE
1.0 %
Select M1: LIMIT RATE from the setting item selection menu.
The currently set rate-of change limit value appears.
M1: LIMIT RATE
1
.0%
The cursor appears.
Press
further to move the cursor to the desired digit to
change.
M1: LIMIT RATE
1.5
%
Change the number of the digit.
To change other digit, press
under this condition to move
the cursor to that digit and change the number there.
M1: LIMIT RATE
1.5 %
The display blinks and the set value is displayed for
confirmation.
Press
MENU/ENT
again to write the data. Then the cursor
disappears and the display returns to the condition that the
setting value is displayed.
M
1: LIMIT RATE
Returns to the menu of setting item selection.
Note: If a value outside of the settable range is tried to set, *H. OVER SPEC. appears and the value returns to
the previously set value. Try to set a new value again.