B. Power Frequencies
Power frequencies refer to 50 or 60 Hz signals, and their harmonics, that can be traced
without the use of a transmitter.
60: Best for general locating of passive power.
60H (high harmonic): If the 60 choice appears to be responding slowly, or poorly, then
60H is the second choice for locating of passive power.
60L (low harmonic): Third choice for passive power locating. May be used when 60 or
60L is weak or erratic. 60L may be the best choice when locating primary power cables.
120 Hz: Used for locating rectified AC power signals, often found on pipelines using
impressed current cathodic protection.
1. Press Locate/OK [5]
2. Press Cable/Pipe [SK]
3. Press Freq [SK]
4. Press Power [SK Toggle] until the desired frequency is displayed in the soft key
command [9] (“Power” 60, 60L, 60H, or 120).
5. Press Locate/OK [5] to return to Locate mode.
All U.S. receivers default to 60 Hz.
To set the receiver to detect 50 Hz signals refer to Enabling/Disabling Frequencies
section of this manual.
C. Passive Frequencies
The receiver (without a 3M
Dynatel
Transmitter 2200 Series) can be used to detect
some CATV cables (31.5 kHz). (A horizontal-scan television NTSC must be turned on to
generate this frequency.)
1. Press Locate/OK [5]
2. Press Cable/Pipe [SK]
3. Press Freq [SK]
4. Press Pasv [SK Toggle]
5. Press Locate/OK [5] to return to Locate mode.
D. Auxiliary Frequencies
Auxiliary frequencies are signals generated from remote location transmitters, or
frequency generating transmitters.
1. Press Locate/OK [5]
2. Press Cable/Pipe [SK]
3. Press Freq [SK]