176
however be at least four T-stops apart, in order to
define the iris table.
If the iris scale is not linear, all the T-stops must be
programmed.
After programming the iris table, the T-stops on the iris
ring of the lens must be controlled by adjusting with
the handwheel and visually checking the lens.
If the created iris table should remain available for later
use, it must be stored. This also applies when an iris table
has been re-edited.
• Storing iris tables:
The handwheel must then be turned in the table menu
(TBL LOAD, TBL DEL, TBL EDIT, TBL STORE) until
‘STORE’ is displayed in the second line.
Confirm the selection by pressing the SEL button –
‘STORE’ is displayed in the first line,
and the number of the memory area is shown in the
second line (10 memory areas are available).
Select the number of the required memory area using
the handwheel and store the iris table by pressing the
SEL button.
Note down the number of the memory area together
with the programmed lens to simplify activating lenses
at a later time.
Quick Guide