Setup with Iris control
A CLM-2 motor must be mounted if the iris of the lens is
to be controlled by the WRC-1.
Mounting the CLM-2 motor with/without console
Console order number: K2.52035.0
• Flip up the locking lever ➪ photo and screw back
the ballcatch ➪ photo with a screwdriver until it
disappears completely in the bracket.
• Push the tube ➪ photo flush into the console recep-
tacle, taking care that the slit in the tube points to-
wards the ballcatch.
• Screw the ballcatch out of the bracket until the tube
can no longer be pushed out of the bracket.
• Turn the locking lever until a slight resistance can be
felt, then press the lever downwards.
• Fasten the motor unit CLM-2 to the console tube.
locking lever tube
receptacle
ballcatch
Setup