Panasonic AJ-HD150FE VCR User Manual


 
– 105 –
Displaying the “HOURS METER” information
Turn the search dial to move the cursor ( * ). The description for the item where the cursor is located is shown as a
superimposed display.
Item No. Item Description
H00 OPERATION
H01 DRUM RUN
H02 TAPE RUN
H03 THREADING
H11 DRUM RUN r
H12 TAPE RUN r
H13 THREADING r
H30 POWER ON
<Notes>
The resettable items in the “HOURS METER” information are reset by the shop when performing maintenance or
other work.
The search buttons and the search dial cannot be operated while the DIAG menu is displayed.
If “T&S&M” is selected in the setup menu No. 006 (DISPLAY SEL), a message appears in the mode display
whenever a warning or error occurs. When multiple events occur, the event with the highest priority is displayed.
Priority Display Description
High Error messages
(See error message table)
INT SG
NO INPUT
Warning messages
(See warning message
Low table)
Warning messages
Priority Monitor display Description VTR operation
High FAN STOP Operation continues
NO RF
Operation continues
SERVO NOT
LOCKED
Operation continues
LOW RF
Operation continues
HIGH ERROR
Operation continues
Low RATE
Error messages
Displays the time that the power has been supplied in one-hour units.
Displays the time that the drum has been rotating in one-hour units.
Displays the time that the tape has been running during FF, REW, PLAY, SEARCH (JOG,
VAR, SHTL), REC, and EDIT modes (except for STILL in the JOG, VAR or SHTL mode) in
one-hour units.
The number of times for threading/unthreading is displayed in single units.
Displays the time that the drum has been rotating in one-hour units. (Can be reset)
Displays the time that the tape has been running during FF, REW, PLAY, SEARCH (JOG,
VAR, SHTL), REC, and EDIT modes (except for STILL in the JOG, VAR or SHTL mode) in
one-hour units. (Can be reset)
The number of times for threading/unthreading is displayed in single units. (Can be reset)
The number of times the power has been turned on is displayed in single units.
When an abnormal operation is detected in this unit, the AUTO OFF lamp lights up
and an error message is displayed.
When INT SG is selected in setup menu No.600 (VIDEO IN SEL) or No.700
(AUDIO IN SEL), pressing REC button or EDIT button causes the display to be
given for 2 sec. from the beginning (EE mode).
Similarly in edit mode, the display will be given for 2 sec. from the beginning.
In case of no input signal at the connector selected by setup menu No.600 (VIDEO IN SEL)
or No.700 (AUDIO IN SEL) except analogue audio, pressing REC button or EDIT button
causes the display to be given for 2 sec. from the beginning (EE mode).
Similarly in edit mode, the display will be given for 2 sec. from the beginning.
When a warning occurs in this unit, the warning lamp lights up and a warning
message is displayed. When multiple warnings occur, the warning with the highest
priority is displayed.
This is displayed when the fan motor stops.
This appears when a blank part of the tape lasting for 1 or more
seconds has been detected during playback.
When all the following conditions have been met, it will be recognized
as a blank part.
· When no signals are output from any of the heads
· When the playback data cannot be read
· When CTL is not present
This is displayed when the servo is not locked for three or more
seconds during playback, recording, or editing.
This is displayed when envelope levels approximately 1/3 that of
normal levels are detected for more than one second during
playback, recording, or editing.
This is displayed when the error rate increases and correction/
interpolation is performed on either the video or audio playback signal.