Setup menus
USER menu
<TIME CODE>
Item Setting
No.
Superimposed
No.
Superimposed
Description
display display
500 VITC 0000 BLANK
BLANK
0001 THRU
501 VITC 0000 10L
POS-1 : :
0006 16L
::
.0010 20L
502 VITC 0000 10L
POS-2 : :
0008 18L
::
0010 20L
503 REGEN 0000 REGEN
0001 PRE
504 RUN MODE 0000 REC
0001 FREE
505 TCG 0000 TC&UB
REGEN 0001 TC
0002 UB
506 REGEN 0000 AS&IN
MODE 0001 ASSEM
0002 INSRT
0003 MANU
507 EXT TC SEL 0000 LTC
0001 SLTC
0002 SVITC
508 BINARY 0000 000
GP 0001 001
0002 010
0003 011
0004 100
0005 101
0006 110
0007 111
The underline on the setting item denotes the initial setting.
For selecting whether to output the VITC signal at the posi-
tions selected by setup menu items No. 501 (VITC POS-1)
and No. 502 (VITC POS-2).
0: VITC signals are not output.
1: VITC signals are output.
<Note>
This setting takes effect only with the SD output.
This sets the position where the VITC signal is to be inserted.
<Notes>
The same line as the one used for the setup menu item
No. 502 (VITC POS-2) setting cannot be set.
This setting takes effect only with the SD output.
This sets the position where the VITC signal is to be inserted.
<Notes>
The same line as the one used for the setup menu item
No. 501 (VITC POS-1) setting cannot be set.
This setting takes effect only with the SD output.
This sets the synchronization of the internal time code
generator.
0: The time code reader is synchronized with the time code
read from the tape.
1: What the time code generator will be synchronized with can
be preset using either the operation panel controls or the
remote controller.
This sets the operation mode in which the time code of the
internal time code generator is to advance.
0: The time code advances only during recording.
1: It advances while the power is on regardless of the mode
which has been established.
This selects the signal to be regenerated when the TCG (time
code generator) is in the REGEN mode.
0: Both the time code and user’s bit are regenerated.
1: Only the time code is regenerated.
2: Only the user’s bit is regenerated.
This selects whether the time code is to be regenerated during
automatic editing using the unit’s control panel.
0: The time code is regenerated with assemble or insert
editing.
1: The time code is regenerated with assemble editing.
2: The time code is regenerated with insert editing.
3: The setup menu item No.503 (REGEN) setting is followed.
This selects the time code in use of external time code.
0: LTC of TIME CODE IN terminal is used.
1: LTC information applied to serial signal is used.
2: VITC information applied to serial signal is used.
This sets the usage status of the user bit of the time code
generated by the TCG.
0: NOT SPECIFIED (character set not specified)
1: ISO CHARACTER (8 bits character set based on ISO646,
ISO2022)
2: UNASSIGNED 1 (undefined)
3: UNASSIGNED 2 (undefined)
4: UNASSIGNED 3 (undefined)
5: PAGE/LINE
6: UNASSIGNED 4 (undefined)