Panasonic AJ-HD150FE VCR User Manual


 
– 116 –
Connector signals
PARALLEL REMOTE (50P)
Pin No.
Signal
Pin No.
Signal
Pin No.
Signal
1 REC COMMAND 20
STBY ON/OFF COMMAND
33 EJECT STATUS
2 PLAY COMMAND 21 ERR 0 STATUS* 34 ERR 2 STATUS*
3 FF COMMAND 23 CUE COMMAND 39-40
REC INH MENU STATUS
4 REW COMMAND 24 ERR 1 STATUS* 41 CUE STATUS
5 STOP COMMAND 26 +POWER 42 REMOTE STATUS
10
LOCAL ENABLE COMMAND
27 REC STATUS 45 LOCAL STAUTS
11 EJECT COMMAND 28 PLAY STATUS 46 STBY STATUS
12 IN SET COMMAND 29 FF STATUS 47 GND
13
REC INHIBIT ON COMMAND
30 REW STATUS 49-50 GND
15
LOCAL DISABLE COMMAND
31 STOP STATUS
*50-pin error status table
RS-232C REMOTE (25-pin D-SUB crossover cable supported)
Pin No. Abbreviation Circuit Description
1 FRAME GROUND Protective ground Frame ground
2 RxD Received data Sends data to the PC.
3 TxD Transmitted data Receives data from the PC.
4 CTS Clear to send Shorted with pin 5.
5 RTS Request to send Shorted with pin 4.
6 DTR Data terminal ready No processing
7 GND Signal ground Signal ground
20 DSR Data set ready
Positive power output after communication
enable status
ENCODER REMOTE (15P)
Pin No.
Signal
1 FRAME GROUND
2 REM (G)
3 REM RX (X) REMOTE CONTROL PROTOCOL RECEIVE
4 REM TX (X) REMOTE CONTROL PROTOCOL TRANSMIT
5 REM RX (Y) REMOTE CONTROL PROTOCOL RECEIVE
6 REM TX (Y) REMOTE CONTROL PROTOCOL TRANSMIT
Pin21/
ERROR 0
0
0
0
0
1
1
1
1
Pin24/
ERROR 1
0
0
1
1
0
0
1
1
Pin 34/
ERROR 2
0
1
0
1
0
1
0
1
Output priority
sequence
1
4
3
2
----
----
----
----
AJ-HD150
VTR status
SERVO NOT LOCKED
SEVO LOCKED
HIGH ERROR (UMBER)
HIGH ERROR (RED)
1:Active_L 0:Open