Message Cause and Solution
Sub-Camera is not
connected.
Check the connection.
A cable or cord is not properly connected.
Check that all cables to the KX-VC500 are connected properly.
(Page 52)
The sub video camera is not turned on.
Turn on the sub video camera.
Sub-Camera source is not
compatible.
A cable or cord is not properly connected.
Check that all cables to the KX-VC500
are connected properly.
(Page 15)
The signal input from the sub video camera is invalid.
A valid signal cannot be received from the connected sub video camera.
Contact your dealer.
Check the display resolution.
The computer’s display resolution or refresh rate is incompatible with
the KX-VC500.
Set your
computer’s resolution and refresh rate to a setting compatible
with the KX-VC500. (Page 50)
This IP Address is already in
use.
On the network you are using, another device is already using the IP
address you have input for the KX-VC500.
Make sure that all devices on the network have unique IP addresses
assigned.
Cooling Fan Malfunction.
Please turn off the system
and call for service.
The CPU cooling fan within the device has stopped.
Quickly turn off the power. Contact your dealer.
Check main camera setting
<Check camera>
Set the main camera
HDMI output to 1080i.
<Safe mode>
If [#] is pressed, the system
enters safe
mode after restart.
A standard definition (640 ´
480p, 720 ´ 480p) video camera signal has
been detected.
Change the video camera’s resolution to HD (1920 ´ 1080i).
Note
If you enter Safe Mode during a video conference call, the call will
be disconnected.
Check main camera setting
<Check camera>
Set camera operating
frequency to nHz.
<Safe mode>
If [#] is pressed, the system
enters
safe
mode after restart.
Note
The field frequency
setting of the
KX-VC500 (50 or 60)
is represented by n.
A video camera with a different field frequency to the
KX-VC500 has
been detected.
Use a video camera with the same field frequency as the
KX-VC500.
Note
If you enter Safe Mode during a video conference call, the call will
be disconnected.