Panasonic WJ-RT416 DVR User Manual


 
44
Connection with PS·Data systems
This is an example of connection when the unit is used together with the PS·Data devices.
If a connected system controller is PS·Data compatible, it is possible to operate this unit or connected devices using the sys-
tem controller.
Use the RS485 cable provided with the system controller.
Important:
Terminate both devices on both ends of the connection. Refer to the respective operating instructions for the descriptions
of how to terminate. Termination of this unit can be set with the mode selection DIP switch on the rear panel. (See page
47.)
When connecting a PS·Data compatible device, it is necessary to set each item of "PS.Data Setup" of "Communication
Setup" according to the system configuration.
The following are available PS·Data compatible devices.
System controller: WV-CU650 (Ver 2.10 or later)
Data multiplex unit: WJ-MP204
Matrix switcher: WJ-SX650 (Ver. 3.00 or later)
(Any other PS·Data compatible devices are not to be connected.)
When connecting a single unit with a controller
AUX IN
AUDIO OUT
IN
OUT
16 15 14 13 12 11 10 9 8 7 6 5 4 3
531
642
12
14 13 12 11 10 9 8 7 6 5 4 3 2 116 15
MONITOR1 MONITOR2
RS485(CAMERA)
MODE
12
DATA
10/100BASE-T COPY1
ALARM IN/CONTOROL
AUDIO IN
SIGNAL GND
POWER
ON
OFF
AC IN
AUDIO IN/ALARM OUT
VIDEO
SERIAL
This unit
1
ON
2
Mode selection
DIP switches
A B
1
3
2
4
6
5
7
9
8
0
SYSTEM CONTROLLER
Controller
Termination: ON
Unit Address: 1
RS485 cable
(provided with the controller)
"PS.Data Setup" of "Communication Setup"
on the Setup Menu
Unit Address (System): 1
Unit Address (Controller): 2