ACCULINK 316x DSU/CSU
C-28 January 1997 3160-A2-GB21-50
Management Configuration
Options
The Management configuration options are divided
into two tables as follows:
• General Management Configuration Options
(Table C-9)
• Management Trap Configuration Options
(Table C-10)
NOTE
A circular symbol (F) identifies
configuration options that are
available on standalone
DSU/CSUs only. A triangular
symbol (Y) identifies
configuration options that are
available on carrier-mounted
DSU/CSUs only.
Table C-9
(1 of 7)
General Management Configuration Options
SNMP Mgt: Disab
Next Enab Disab Prev
SNMP Management Enable. Specifies whether the DSU/CSU responds to SNMP session requests.
Enab – The DSU/CSU responds to SNMP session requests.
Disab – The DSU/CSU does not respond to SNMP session requests.
NMS Valid: Disab
Next Enab Disab Prev
NMS IP Validation. Specifies whether the DSU/CSU validates (for security reasons) the IP address of an SNMP manager
attempting to access the DSU/CSU. Allowable addresses are specified using the NMS
n
IP Adr configuration option.
Enab – The DSU/CSU validates the IP address of SNMP management systems attempting to access the DSU/CSU.
Disab – The DSU/CSU does not validate the IP address of SNMP management systems.
Num Sec Mgrs: 1
Next 1 2 3 4 5 6 7 8 9 10 Prev
Number of Security Managers. Specifies the number of SNMP managers that are allowed to access the DSU/CSU.
NOTE: You must configure an IP address for each SNMP manager that is allowed access to the DSU/CSU. Allowable
addresses are specified using the NMS
n
IP Adr configuration option.
NMS
n
IP Adr:
Next Edit Clear Prev
NMS Manager
n
IP Address. Specifies the allowable IP address of an SNMP manager attempting to access the
DSU/CSU. The manager number (
n
) is specified by the Num Sec Mgrs configuration option.
Edit – Allows you to edit and/or display the allowable IP address for the SNMP manager.
Clear – Allows you to clear the allowable IP address for the SNMP manager. The IP address is set to 000.000.000.000.