Paradyne 3160-A2-GB21-50 Cable Box User Manual


 
ACCULINK 316x DSU/CSU
4-18 January 1997 3160-A2-GB21-50
Starting a Line Loopback
The Line Loopback command (LLB) loops the
received signal on the network interface back to the
network without change.
496-14319-02
CSUDSU
NETWORK
INTERFACE
DTE
(DSX-1)
ALL 1s
LLB
PORT 1PORT 2
ALL 1s
ALL
1s
To perform a Line loopback,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
F1
Test:
Rlpbk Lpbk Ptrns
F2
F3
3. From the Loopback screen, select LLB.
F1
Loopback:
Abort LLB PLB
F2
F3
Test Started appears on Line 2. If a line loopback
is already in progress, the Already Active
message appears. If an invalid combination of
loopbacks is in progress, the error message Invld
Test Combo appears (see Table 4-8 for valid
loopback test combinations).
Starting a Payload Loopback
The Payload Loopback command (PLB) loops the
received signal on the network interface back to the
network. The signal is looped back as close to the DTE
Drop/Insert (DSX-1) port as possible (after it has passed
through the framing circuitry of the DSU/CSU). Framing
CRCs and BPVs are corrected.
496-14316-02
CSUDSU
NETWORK
INTERFACE
DTE
(DSX-1)
ALL 1s
PLB
PORT 1PORT 2
ALL 1s
ALL
1s
To perform a Payload loopback,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
F1
Test:
Rlpbk Lpbk Ptrns
F2
F3
3. From the Loopback screen, select PLB.
F1
Loopback:
Abort LLB PLB
F2
F3
Test Started appears on Line 2. If a Payload
loopback is already in progress, the Already
Active message appears. If an invalid combination
of loopbacks is in progress, the error message
Invld Test Combo appears (see Table 4-8 for
valid loopback test combinations).