ACCULINK 316x DSU/CSU
4-6 January 1997 3160-A2-GB21-50
6. When you press F2 from the User Registers
screen, the User registers for the 24-hour total
interval appear.
F1
User 24 Hour:
VldIntvl =
xx
F2
F3
7. When you press F3 from the User Registers
screen, the interval screen appears. Use this screen
to choose the specific 15-minute interval.
F1
User Intvl: 01
Up Down Dsply
F2
F3
8. Use the and keys to position the cursor
under the first or second digit in the interval
number displayed, then use the F1 (Up) and
F2 (Down) keys to increment/ decrement the
number.
9. When you have selected the number of the interval
you want to display, press F3 (Dsply) to display
the registers for the interval selected. Use the
scroll keys to view additional register information.
F1
User Intvl:
xx
ES=
xxx
F2
F3
You can reset the performance registers via the ClrReg
command in the Control branch of the front panel menu.
To clear the performance registers,
1. From the top-level menu screen, press the key
until the Ctrl selection appears on the screen.
2. Select Ctrl.
3. From the Control screen, press the
key until
the ClrReg selection appears on the screen.
4. Select ClrReg.
F1
Control:
Rel LED ClrReg
F2
F3
5. From the Clear Prf Regs screen, press F1 to clear
the User registers.
F1
Clear Prf Regs:
User Prt1 Prt2
F2
F3
If you selected User, the User performance
registers are cleared, all accumulators are reset to
zero, and all status registers are cleared. The
current interval timer, the number of valid
intervals count, and the total 24-hour counts are
reset to zero. The Command Complete message
then appears.