Paradyne 3160-A2-GB21-50 Cable Box User Manual


 
ACCULINK 316x DSU/CSU
4-14 January 1997 3160-A2-GB21-50
Table 4-7
Test Jack Functions
Test Jack Name
Function
NET In
(Network In)
A break-in test jack that allows a signal to be inserted toward the network by
external test equipment.
NET Out
(Network Out)
A break-in test jack that interrupts the signal coming from the network and allows it
to be terminated by the external test equipment.
EQPT In
(Equipment In)
A break-in test jack that allows a signal to be inserted toward the terminal
equipment (DTE) by external test equipment.
EQPT Out
(Equipment Out)
A break-in test jack that interrupts the signal coming from the terminal equipment
(DTE) and allows it to be terminated by the external test equipment.
MON In
(Monitor In)
A monitor jack that is controlled by the Mon (Monitor) branch of the menu tree. If it is
set to EQPT (the default), this jack monitors the signal going into the terminal
equipment (DTE). If it is set to NET, this jack monitors the signal going into the
network.
MON Out
(Monitor Out)
A monitor jack that is controlled by the Mon (Monitor) branch of the menu tree. If it is
set to EQPT (the default), this jack monitors the signal coming from the terminal
equipment (DTE). If it is set to NET, this jack monitors the signal coming from the
network.