Pelco C2908M-B Universal Remote User Manual


 
52 C2908M-B (4/05)
TERMINAL PROGRAM TRANSMITTER MENU STRUCTURE
The following describes the terminal program transmitter menu structure. The menu items and commands are enclosed in single quotation
marks. Do not enter the quotation marks. Information and current settings are displayed to the right of the commands. Refer to the Command
Reference section for descriptions of the commands.
Main Menu
‘v’ video
‘i’ IP
‘r’ RCP+
‘m’ misc
‘?’ This Menu
‘q’ exit/logout
v – Video Menu
‘e’ Encoder Settings
‘t’ set video input termination 1(1)
‘a’ adapt std res (e.g., CIF) to NTSC: 1
‘x’ Leave this Menu
‘?’ This Menu
e – Encoder Settings Submenu
‘e’ Select Encoder 1
‘p’ Parameter set: 1
‘n’ Parameter set name:
‘k’ min frame dist [1…]: 1
‘r’ Encoder Bitrate [kBit]: 5000
‘Q’ I Quantizer: 8
‘q’ P Quantizer: 8
‘i’ I frame distance: 0
‘u’ I update distance: 132
‘s’ frame size (res): 3
‘w’ custom width: 432
‘h’ custom height: 288
‘d’ reset to default
‘x’ Leave this Menu
‘?’ This Menu
t – Set Video Input Termination Submenu
Set video input termination: (0: no termination, 1: termination)
a – Adapt Standard Resolutions Submenu
Adapt standard resolutions (e.g., CIF) to NTSC? (0: no, 1: yes)
i – IP Menu
An asterisk (*) means a reset of the NET300 is necessary after a change. Reset by cycling the power.
‘i’ (*) local IP 10.0.0.1
‘s’ (*) local subnet mask 255.255.255.0
‘g’ (*) local gateway 0.0.0.0
‘r’ remote IP 0.0.0.0
Mac Address 00-07-5f-50-00-11
‘a’ Auto Connect Off
‘m’ Set HD/FD 10/100 auto mode
‘p’ Ping remote IP 0.0.0.0
‘l’ RTP Packet Loss Stats
‘x’ Leave this Menu
‘?’ This Menu