90 C2908M-B (4/05)
Figure 56. Using PelcoNet with CM6800 and KBD200A to Provide Remote Control
ETHERNET
CONNECTION
TO NETWORK
(LAN/WAN)
SPECTRA
COAXITRON
PROTOCOL
PELCONET TRANSPARENT
DATA PORT
2 RX..................................
3 TX...................................
5 GND............................
CM6800-48X8
COM 2
8 TX
1 RX
5 GND
6800 MATRIX COM 2
PORT SETTINGS:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
NOTE: FIRMWARE VER 4.0 OR LATER REQUIRED. SET KEYBOARD DIP SWITCHES SWITCH
6 ON, SWITCHES 5 AND 8 OFF, SWITCHES 1 - 4 FOR ADDRESS ACCORDING TO THE
TABLE IN THE KBD200A MANUAL.
RECEIVER
TX -
RX -
KBD200A
STRAIGHT
CABLE
12 VAC
1
2
3
4
8
7
6
5
RX +
TX +
2-RX
3-TX
5-GND
RJ-45 WALL BLOCK
AND STRAIGHT
CABLE SUPPLIED
PELCONET CM6800 ASCII SETUP
PELCONET REMOTE KBD200A ASCII MODE SETUP
TRANSMITTER
RS232/422/485
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
TRANSPARENT DATA PORT
USING INTERNET EXPLORER;
SET TRANSPARENT DATA
PORT SETTINGS:
TRANSPARENT DATA PORT
USING INTERNET EXPLORER; SET
TRANSPARENT DATA SETTINGS
ON BOTH PELCONET RECEIVER
AND TRANSMITTER:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
RS232/422/485
ETHERNET
CONNECTION
TO NETWORK
(LAN/WAN)
Video Out
MONITOR
RX -
STRAIGHT
CABLE
1
2
3
4
8
7
6
5
TX -
2-RX
3-TX
5-GND
Video In
GND