Pelco C2908M-B Universal Remote User Manual


 
C2908M-B (4/05) 83
CONNECTING PELCONET TO A CM6700 AND KBD200A FOR REMOTE ASCII CONTROL
Refer to Figure 49. This configuration lets an operator view and control cameras with a remote KBD200A keyboard.
Figure 49. Using PelcoNet with CM6700 and KBD200A to Provide Remote Control
NOTE: FIRMWARE VER 4.0 OR LATER REQUIRED. SET KEYBOARD DIP SWITCHES SWITCH
6 ON, SWITCHES 5 AND 8 OFF, SWITCHES 1 - 4 FOR ADDRESS ACCORDING TO THE
TABLE IN THE KBD200A MANUAL.
RECEIVER
TX -
RX -
KBD200A
STRAIGHT
CABLE
12 VAC
1
2
3
4
8
7
6
5
RX +
TX +
2-RX
3-TX
5-GND
PELCONET REMOTE KBD200A ASCII MODE SETUP
TRANSPARENT DATA PORT
USING INTERNET EXPLORER; SET
TRANSPARENT DATA SETTINGS
ON BOTH PELCONET RECEIVER
AND TRANSMITTER:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
RS232/422/485
Video Out
ETHERNET CONNECTION
TO NETWORK (LAN/WAN)
13579
246810
11
12 14
13 15
16
1
2
VIDEOINPUTS
VIDEOOUTPUTS
ALARMS
(1-9 )
ALARMS
(10-18)
CO M1(1-6 )
CO M2(7-12)
CONTROL
OUTPUTS
REMOTE KEYBOARD(S)
LOCAL
KEYBOARD
123456789
10
11
12 13141516 1718
123456789
10
11
12
0123
F
2
F
3
N
O
N
C
C
O
M
TT RR
+ +
12345678
ON
12345678
ON
RS-422/485
ON OFF
KEY
RS-232
SW5 DIPSWITCH SETTINGS
SET DIP SWITCH (SW5) ON
CM6700-MXB TO RS-232 MODE
TRANSMITTER
RS232/422/485
Video In
CM6700 MATRIX COM 2
PORT SETTINGS:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
ETHERNET CONNECTION
TO NETWORK (LAN/WAN)
2 RX......................7 TX
3 TX.......................12 RX
5 GND...................9 GND
CONNECT PELCONET TO
6700 VIA RS-232 PORT
MONITOR
SPECTRA COAXITRON
PROTOCOL
SPECTRA
PELCONET CM6700-MXB
TRANSPARENT COM 2 (7-12)