Pelco MX4004 Home Theater Server User Manual


 
Pelco Manual C1995M-A (10/01) 21
POWERING THE MULTIPLEXER
Use the following procedure to initialize multiplexers being powered up for the first time or
after extended storage. This clears any random data remaining in the multiplexer and
initializes the memory for user programming.
1. Turn on power to cameras, monitors, and any equipment connected to the multiplexer.
2. Plug the transformer cord into the multiplexer.
3. Hold down the VIEW button on the multiplexer’s front panel while plugging the wall
transformer into an electrical outlet. The monitor displays PLEASE WAIT and begins a
20-second countdown. After the countdown finishes, this initialization screen disap-
pears, all programming menus are at their default settings, and the multiplexer is
ready to use.
MINIMUM PROGRAMMING
As a minimum, you must program the following to operate your system:
Video Termination
Set terminations for all video inputs with the DIP switches on the rear of the multiplexer.
Coaxitron Format (Camera Protocol)
Set in respective Camera menu for PTZ camera control.
Unit ID and Communication Type
Set in the Advanced System Setup menu.
Refer to the
Programming
section to program the multiplexer from the front panel. Refer to
your keyboard manual to program the multiplexer with the keyboard, or refer to the
Specific
Applications Programming
section in this manual.
NOTE:
If the reach be-
tween the electrical outlet
and the VIEW button is too
far, try the following. Detach
the transformer cord from
the rear of the multiplexer,
plug into the outlet first, and
then plug the transformer
cord into the multiplexer. A
rack-mounted unit may
require two people.