Capture the Glitch with the Timing Analyzer and
Oscilloscope
The timing analyzer runs, triggers, and then arms the oscilloscope. Notice
the slight delay between the glitch displayed by the timing analyzer and the
oscilloscope. This is caused by the intermodule bus when one instrument
arms another. In the following exercise, you will align the glitch in the two
displays.
1
Highlight the Group Run field, and press the Select key. Highlight Single
in the pop-up menu, and press the Select key.
2 Highlight the s/Div field, then rotate the knob to change the s/Div to
20 ns.
You will now see the glitch on both the oscilloscope waveform, and on
TCOUNT 7 in the timing analyzer section of the display.
Capturing the Glitch on the Oscilloscope
Result The glitch is captured and displayed by the analyzer and oscilloscope.
The glitch captured by
the oscilloscope.
The glitch captured by
the timing analyzer.
Triggering the Oscilloscope with the Timing Analyzer
Capture the Glitch with the Timing Analyzer and Oscilloscope
8-14