HP (Hewlett-Packard) 1660 TV Converter Box User Manual


 
Clear the Timing Analyzer Trigger
Clearing the timing analyzer trigger sets the specification to "don’t care". By
doing this, the timing analyzer will trigger as soon as it is armed by the state
analyzer.
1
Press the Trigger MENU key.
2 Highlight the Modify Trigger field on the right side of the screen, and
press the
Select key.
3 Highlight the Clear Trigger field, press the Select key, and choose All
from the pop-up menu.
Result The timing analyzer trigger specification is set to a "don’t care" state.
Set Up the State Trigger Specification
1 Press the Trigger MENU key. Highlight Trigger MACHINE 1 in the pop-up
menu, and press the
Select key. The Trigger MACHINE 1 menu is
now displayed. If this is not the case, press the
Trigger MENU key
again, then choose
Trigger MACHINE 1 from the pop-up menu.
2 Highlight the 1 field in the State Sequence Levels box of the Trigger
menu. Press the
Select key.
3 Highlight the field to the right of While storing, and press the Select key.
Highlight
anystate in the pop-up menu, and press the Select key.
4 Press the Done key to close the Sequence Level 1 pop-up menu.
Result The state analyzer trigger specification is now:
Level 1 - While storing "anystate", TRIGGER on "a" 1 time
Level 2 - Store "anystate"
The trigger term "a" is assigned the hex value FF.
Mixed Mode - Correlation of State and Timing Data
Clear the Timing Analyzer Trigger
5-7