Load the Inverse Assembler and Sample Listing
In this exercise you will load a configuration file and the inverse assembler to
translate the binary data. You will not be making the measurement because
the training board does not have a microprocessor.
1
Place the flexible disk labeled "Logic Analyzer Training Kit
Configurations" in the disk drive.
2 Press the Config MENU key.
3 Highlight the field to the right of Type in the Analyzer 1 box. Press the
Select key and choose State in the pop-up menu.
4 Press the System MENU key.
5 Highlight the field to the right of System, press the Select key, and
choose
Flexible Disk in the pop-up menu.
6 If you are using an HP 1660 series analyzer, load the Analyzer with
these files:
IA386E (inverse assembler)
TRC_386._A. (sample listing)
7 If you are using an HP 1670 series analyzer, load the Analyzer with
these files:
ICPU32 (inverse assembler)
TRC_32._A (sample listing)
Result Both the inverse assembler and the listing are loaded onto the analyzer with
the necessary configurations.
See Also "To Load a Configuration File" in chapter 11 for more information.