No./Item Description of setting
115*
1
EJECT SW
INH
For setting whether to restrict the operation of the
EJECT button on the front panel.
0000 REC :
Operation is inhibited while the unit is in the
recording mode.
0001 OFF :
The EJECT button can be operated in all operation
modes.
118*
1
SP MODE
INH
For selecting whether to enable or disable recording
on a tape which has been recorded using a format
other than DVCPRO HD-LP.
0000 OFF :
Recording onto the cassette tape is enabled.
0001 ON :
Recording onto the cassette tape is disabled.
119*
1
CONFI REC
For selecting whether or not to perform simultaneous
playback during normal recording (Other than the
frame-by-frame shooting).
0000 OFF :
The output for simultaneous playback during
normal recoding is switched in accordance with the
menu item No.140 OUTPUT.
EE: EE output
TAPE: Simultaneous playback output
0001 ON :
Simultaneous playback during normal recoding is
performed at all times, regardless of the setting of
the menu item No.140 OUTPUT.
134
ALARM
BEEP
For selecting the alarm sound for condensation,
termination of the tape (remaining time of about 2
minutes) or running out of battery power.
0000 OFF :
The alarm sound is not activated.
0001 ON :
The alarm sound is activated.
<Note>
If "ON" is selected in menu item No. 152 HUMID
OPE, the alarm sound for condensation is not
activated even if "ON" is selected.
140*
1
OUTPUT
For selecting the output signals.
0000 EE :
<In the STOP mode>:
The input signals selected by the setting of the
INPUT SELECT button are output.
<During recording or editing>:
The input signals selected by the setting of the
INPUT SELECT button are output:
0001 TAPE :
<In the STOP mode>
The signals played back from the tape are output.
<During recording or editing>:
The simultaneous playback signals are output.
<Note>
In order to select the output signals during recording
or editing, set menu item No.119 CONFI REC or
No.302 CONFI EDIT.
No./Item Description of setting
152
HUMID OPE
For setting the unit’s operation when condensation
has formed.
0000 OFF :
The unit does not operate when condensation has
formed.
0001 ON :
It operates even when condensation has formed
but no guarantees are made that the operation will
be trouble-free.
<Note>
Since operating the unit when condensation has
formed may damage the tape or give rise to other
trouble, the “OFF” setting is recommended under
normal circumstances.
154*
1
AUTO BACK
For setting how the follow-on recording function is to
be used.
(For setting the AUTO BACK function operation which
rewinds the tape for several seconds in order to
ensure that the video images follow on one from
another with no disruptions.)
0000 OFF :
The tape is not rewound automatically (no AUTO
BACK).
0001 REC-P :
The tape is rewound (AUTO BACK) during REC
PAUSE, and it then stops in the recording standby
status. (When PAUSE is released, the tape runs
up, and recording starts.)
0002 ALL :
In addition to the function of the 0001 REC-P
setting, the tape is rewound (AUTO BACK) during
REC PLAY, the tape immediately runs up, and
recording starts.