Projector Diagnostics
What can be seen?
A log of the last 5 failures with the run time when the failure happened is documented in the
Projector Diagnostics.
Ho
w to display the Projector Diagnostics?
1. Push the cursor key or to highlight 'Projector diagnostics' (menu 1).
2. Press ENTER to display the projector diagnostic menu (menu 2). The last failure will be displayed.
3. Use the cursor keys to scroll through the failure log.
4. Press ENTER to switch to the voltage diagnostics (menu 3).
5. Press EXIT to return to the projector diagnostics menu.
menu 1
VOLTAGE DIAGNOSTICS
+17V : 16.9 Volt
-17V : -17.1 Volt
+9V : +9 Volt
+12V : +11.9 Volt
-12V : -11.8 Volt
+30V : +29.8 Volt
-40V : -39.8 Volt
+110V : +110 Volt
+210V : +209 Volt
HTHD :
-conv :
+conv :
foc_lo :
foc_hi :
<EXIT> to return.
menu 3
PROJECTOR DIAGNOSTICS
Failure nr : 2
Runtime : 180h 30 min
Projector block nr : 4
Coincidence : ON
Deflection :OFF
SF : yes EHT fail : no
SF vert : no HD EHT : no
SF hor : no Fan Fail : yes
IBCL fail : no
Arrow keys to scroll,
<ENTER> to see the voltages,
<EXIT> to return.
menu 2