Recording settings
How to set 56
English
1
Display the <ALARM REC MODE SET> screen as
explained in "Displaying the recording settings screen",
and then turn the S-dial clockwise. (P39)
The "OFF" field of ALARM RECORDING starts blinking.
2
Set the alarm recording.
1 Turn the J-dial to select ALARM RECORDING
selection, and then turn the S-dial twice clockwise.
Selections:
OFF/ENABLED/AL-REC ON TIMER/AL-REC OFF
TIMER/OLY AL-RC ON TMR
2 Turn the J-dial to select the desired PICTURE
QUALITY, and then turn the S-dial twice clockwise.
After the arrow symbol (=>) the number of alarms that
can be recorded is displayed.
Selections:
BASIC/NORMAL/ENHANCED/FINE/SUPER FINE
Example:
3 Turn the J-dial to switch AUDIO RECORDING "ON",
and then turn the S-dial twice clockwise.
The letter "A" is displayed in front of the recording rate,
and the number of alarms that can be recorded is
displayed after the "=>" symbol.
Example:
4 Turn the J-dial to select the recording pattern
(ALARM INTERLEAVE), and then turn the S-dial twice
clockwise.
Selections: ONLY/SW
If ONLY is selected (Figure 1):
Live video will be recorded only from the camera
where the alarm was detected, until the alarm is
cancelled.
If SW is selected (Figure 2):
Live video will be recorded alternately from the
camera where the alarm occurred and from all
connected cameras.
5 Turn the J-dial to select the REC RATE (example: 5),
and then turn the S-dial clockwise.
Repeat the same procedure to set the DURATION.
3
Press the EXIT/OSD button.
The normal screen is displayed again.
The letter "ALARM" and the number of alarm recordings
are displayed in the operation display.
When an alarm is detected, the "ALARM" field starts
blinking.
If consecutive alarms are detected on the same channel,
depending on the alarm retrigger setting, they may be
counted as one alarm. (P60)
G-1 Alarm recording settings
MENU
(J)
(S)
<ALARM REC MODE SET>
ALARM RECORDING : OFF
PICTURE QUALITY : ENHANCED
AUDIO RECORDING : OFF
ALARM INTERLEAVE : ONLY
REC RATE: 15FPS, DURATION: 20SEC
PRE-ALARM RECORDING : ***
REC RATE: **** FPS, DURATION: ****
=> (01731 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
7.ALARM REC MODE SET
2.RECORD SET
<MAIN MENU>
<RECORD SET>
=> (01387 ALARMS CAN BE RECORDED)
REC RATE: A 15FPS, DURATION: 20SEC
=> (01431 ALARMS CAN BE RECORDED)
11111111111111111111
Alarm detected
Alarm cancelled
Records the channel where the alarm was input until the
alarm is turned off
1 2 1 3 1 4 1 5 1 6 1 2 1 3 1 4 1 5 1 6
Alarm detected
Alarm cancelled
Records the channel where the alarm
was input and the other channels
alternately until the alarm is turned off
Alarm channel
Normal recording
02
EXIT/OSD
01-01-06 00:00:00 REC REPEAT EN A ALARM 0000
Alarm total
Alarm indicator