List of camera addresses
Under the RS-485 setting, depending on the address of the set DVR, the address of the camera control setting cannot be
modified. For example, if the address of the DVR is "004", the address of the camera (CH) 1 is preset to 049.
Note:
In the case of the system controller (VSP-9000), the address 000 can be set but cannot be specified and therefore cannot be
operated.
When using the VSP-9000 system controller’s SSP (SANYO’s security serial protocol) to operate a camera that is connected to the
DVR, make sure that Address for DVR connected to camera (A), Channel for DVR (B) and SSP ADDRESS for CAMERA (C) have
been set correctly. If the camera’s address and the channel for DVR are incorrect, the camera cannot be operated.
CH 001 002 003 004 005 006 007 008
000,
009 ~ 127
1 001 017 033 049 065 081 097 113 – – –
2 002 018 034 050 066 082 098 114 – – –
3 003 019 035 051 067 083 099 115 – – –
4 004 020 036 052 068 084 100 116 – – –
5 005 021 037 053 069 085 101 117 – – –
6 006 022 038 054 070 086 102 118 – – –
7 007 023 039 055 071 087 103 119 – – –
8 008 024 040 056 072 088 104 120 – – –
9 009 025 041 057 073 089 105 121 – – –
10 010 026 042 058 074 090 106 122 – – –
11 011 027 043 059 075 091 107 123 – – –
12 012 028 044 060 076 092 108 124 – – –
13 013 029 045 061 077 093 109 125 – – –
14 014 030 046 062 078 094 110 126 – – –
15 015 031 047 063 079 095 111 127 – – –
16 016 032 048 064 080 096 112 000* – – –
(A)
(C)