Sanyo DSR-3716 DVR User Manual


 
Recording settings
How to set 60
English
This menu is used to extend the duration of the alarm
recording and to set the display method when an alarm
occurs.
1 ALARM RETRIGGER
This setting controls whether the recording duration will be
extended when another alarm is detected on the same channel
that is currently performing alarm recording.
ON:
(1) If a second alarm is detected during DURATION operation
on the same channel the recording time is prolonged by
the number of minutes set in DURATION from the point
when the second alarm was detected.
(2) If another channel detects a second alarm during
DURATION operation and the same channel detects a
third alarm the first alarm recording finishes when the third
alarm is detected and the third alarm recording starts. If
the alarm is detected on another channel (CH5), the
recording takes place as set in DURATION.
OFF:
(1) Within the set DURATION, alarms detected by the same
channel are not acknowledged, therefore the recording
stops at the end of the DURATION. However, the second
alarm recording is recorded in the first alarm recording.
(2) If another channel detects a second alarm during
DURATION operation and the same channel detects a
third alarm, the first alarm recording finishes when the third
alarm is detected and the third alarm recording starts. If
another alarm is detected on another channel (CH5), the
recording takes place as set in DURATION.
2 MAIN MON. DISPLAY
Selects the screen type to use for display when an alarm is
detected.
NC:
The main monitor will not change, even if an alarm is detected.
FULL: When an alarm is detected, the main monitor will display the
video from that channel in full-screen mode.
9: When an alarm is detected, the main monitor will change to multi-9
screen mode.
16: When an alarm is detected, the main monitor will change to
multi-16 screen mode.
3 ALARM PRIORITY (display when multiple alarms are
detected)
Sets the priority for alarm display to use when multiple alarms
are overlapping.
LAST:
When multiple alarms are overlapping, display is performed in
the priority order. The most recent alarm is given first priority,
then the one detected before that, and so on.
FIRST: When multiple alarms are overlapping, only the alarm
detected first will be displayed. Alarms detected after that will
not be displayed.
However, if the duration of the first alarm is over, alarms that
have remaining durations will be displayed in the order of
detection.
SWITCH: When multiple alarms are overlapping, the alarms will be
displayed in a scrolling fashion, showing each alarm video
for one second.
4 MON. 2 DISPLAY
Selects whether the monitor connected to the MON2 terminal
will be used to display the alarm video.
NC:
When an alarm is detected, the alarm video will not be displayed
on monitor 2.
SWITCH: When multiple alarms are overlapping, the alarms will be
displayed in a scrolling fashion, showing each alarm video
for one second.
LAST: When multiple alarms are overlapping, display is performed in
the priority order. The most recent alarm is given first priority,
then the one detected before that, and so on.
FIRST: When multiple alarms are overlapping, only the alarm
detected first will be displayed. Alarms detected after that will
not be displayed.
However, if the duration of the first alarm is over, alarms that
have remaining durations will be displayed in the order of
detection.
H Alarm operation settings menu description
<ALARM OPERATION SET>
ALARM RETRIGGER : OFF
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC
1
2
4
3
1st Alarm detected 2nd Alarm detected
CH1
ALARM NO. 1
DURATION
1st Alarm detected 3rd Alarm detected
CH1
ALARM NO. 3
DURATION
ALARM NO. 1
CH5 ALARM NO. 2
2nd Alarm detected
1st Alarm detected 2nd Alarm detected
CH1
ALARM NO. 1
DURATION
1st Alarm detected 3rd Alarm detected
CH1
ALARM NO. 1
DURATION
CH5 ALARM NO. 2
2nd Alarm detected